Worcester Greenstar Ri User Manual
※ Download: Worcester greenstar ri manual
It sits in SEDBUK Band A, and is therefore amongst the top energy rated appliances available. If the lower baffle is stuck, it may be 3. Remove cover from control.
Protective clothing, footwear, gloves and safety goggles must be worn as appropriate. A condensate pipe can easily get frozen causing the blockage and the blue light to flash. If I turn the boiler off and restart in the reset position the blue light comes on but the boiler does nothing and then when I move the dial from reset to max the boiler sounds as if it is working and the green light comes on for roughly 5 seconds but then sounds as it is going to explode and the pipe start creaking and the green light goes off and the boiler does nothing. Worcester suggest turning off the boiler, unplugging from the mains and then firing it back up after a few seconds.
Worcester Greenstar Ri Manuals & User Guides - B Hang control on two lugs on boiler framework.
FAILURE TO INSTALL CORRECTLY COULD LEAD TO PROSECUTION. IF YOU ARE IN ANY DOUBT CONTACT THE WORCESTER BOSCH TECHNICAL HELPLINE. WATER TREATMENT: DISTANCE LEARNING AND TRAINING COURSES ARE AVAILABLE FROM WORCESTER... Care should be taken to ensure terminal siting does not cause a nuisance to adjacent properties. NOTE: Carefully cut along perferated line to release wall template. Clear any debris from the site. Remove cardboard packing piece from appliance. After cutting the end must be square and free from burrs to prevent damage to the flue seals. In the example shown using a flue extension with 2 bends will achieve a total length of 1148mm. Locate lugs at top edge of panel A and clip in at base. The boiler will be reset. CAUTION: DO NOT PRESS POWER INDICATOR B TO RESET BOILER. The pH value of the system water must be less than 8 or the appliance guarantee will be invalidated. Inlet Test Nipple Replace controls cover. Note: This boiler is designed with differential of 20°C across the heating system. If the appliance is unused and exposed to freezing conditions; shut off all the mains supplies and drain the system and boiler. Operate the appliance and take note of any irregularities. Refer to Fault Finding for rectification procedures. Adjusting boiler control to service position 2. If necessary flush with clean water. Remove clamping plate K. Flue limit thermostat Remove electrical connections. Unscrew thermostat from flue. IF THIS IS NOT DONE THE BOILER WLL INDICATE ERROR AND WILL NOT FUNCTION. I M PORTANT: E N S U R E TU B E I S REFITTED TO PRESSURE SWITCH 13. Pull heat exchanger assembly up to clear. Reassemble and check combustion as stated in the gas converstion section. H26-545 12 Seal - door WHS Part No. S2, Service mode selector switch 13. Temperature control and lockout reset. Worcester, Bosch cannot be held responsible for costs incurred by persons not deemed to be competent. The electronic control system for this boiler incorporates a blue central indicator. This normally confirms the permanent mains supply but, by flashing at different rates during a fault, provides a guide to the cause as listed. GAS BOILER COMMISSIONING CHECKLIST C O L L E C T I V E M A R K BOILER SERIAL No.
Worcester greenstar ri manual appliance should be serviced annually after installation unless the particular installation conditions and usage demand more frequent services. FAILURE TO INSTALL CORRECTLY COULD LEAD TO PROSECUTION. Explanation 1: Gas Supply The blue light on an RI will flash when it detects no gas supply, or low pressure. Notwithstanding the requirements of BS 6798 and BS 5440 there is no need for ventilation openings to be provided in the compartment because of the low heat loss from the appliance casing, if the clearances shown are maintained. The temperature of each room can be set individually except primary room with the room thermostat using the thermostatic radiator valves. In the case of a suspected fault, refer to the fault finding section of this guide.